18 May 2022: Database Analysis  

Technique Innovation and Clinical Application of Electrical Impedance Tomography: Bibliometric Research from 2001 to 2020

Li Xiao1BCE, Kang Yu1BCE, Ying Cao1CDF, Xiaowan Lin ORCID logo1CDF, Xiao Liu ORCID logo1CDF, Hui Qiao1AE*, Huihui Miao1AEG, Tianzuo Li1AE

DOI: 10.12659/MSM.936327

Med Sci Monit 2022; 28:e936327

0 Comments

Abstract

BACKGROUND: Electrical impedance tomography (EIT) is a new test that has been widely used by clinicians in recent years at bedside or in ICU wards. Studies and publications on EIT increased quickly and the hotspot trends changed; however, the overview and characteristics of such studies have not yet been reported. Therefore, we have attempted to interpret the evolution of EIT and to anticipate its possible future clinical use by conducting a statistical analysis of EIT articles over the past 20 years.

MATERIAL AND METHODS: We analyzed EIT-related articles from 2020 and the 20 years prior, sourced from the Web of Science database. The data collected included the number of articles published, the classification of the articles, basic information, and author affiliation.

RESULTS: Our study retrieved a total of 1427 EIT-related articles through screening, with the most articles published from Chinese authors and the Chinese Air Force Military Medical University, and the most cited article type being EIT-related basic research. Most articles on EIT have been published in the journal Physiological Measurement. Furthermore, the hotspots and research trends of EIT have changed from basic innovation development to clinical application in the past 20 years.

CONCLUSIONS: This paper presents a statistical analysis of articles on EIT over the last 20 years, focusing on trends from the mechanisms of EIT to its clinical use.

Keywords: Anesthesiology, Positive-Pressure Respiration, Respiration, Bibliometrics, Electric Impedance, Humans, Publications, Tomography, X-Ray Computed

Background

Since its discovery, EIT has been widely used in clinics and has now become a new type of imaging tool [1–5]. Compared with other techniques, EIT has the advantages of non-radiation and non-invasiveness, and the imaging results depend on the electrical potential of the chest wall surface. When EIT is conducted, an electric current passes through the set plane, generates a potential gradient on the surface of the chest wall, and displays two-dimensional impedance imaging on the computer. Previous studies have shown that EIT can cause local changes in lung ventilation [6–10]. The final qualitative information extracted by EIT was similar to that reported by computed tomography (CT) or ventilation scintillation [11–13]. EIT can reflect the state of lung ventilation function from the side and can be used as an index to evaluate the effect of positive end-expiratory pressure [10,14], which helps understand the risk of ventilator-induced lung injury [10,14].

EIT can dynamically observe regional lung ventilation [15] and calculate the size of the local mechanical energy. Positive end-expiratory pressure (PEEP) is an important component of mechanical energy. The adjustment of PEEP can affect the distribution of gas in the lungs [16], in turn affecting the magnitude of the local mechanical energy. In recent years, clinicians have used EIT technology to observe the characteristics of moisture distribution and local mechanical energy changes during PEEP titration, which can provide useful information for the setting of PEEP parameters [14].

Bibliometric analysis is a uniform and objective analysis of a number of published papers that have had some influence in a particular line of research [17,18]. We searched databases and found that there are no high-quality bibliometric analyses of EIT. This study aimed to discover the citation trend of published papers on EIT to help understand the current status of EIT research and provide clinicians with better lung function reference indicators.

Material and Methods

SEARCH STRATEGY:

The Web of Science database was used to survey articles on EIT published between 2001 and 2020. The search was conducted using “Electrical impedance tomography” as the title, restricting the article type to “article review” and searching for English language publications only. The following bibliometric information were collected: year of publication; country; journal publication; number of citations; author; grant; discipline; institution; and subject. No other exclusion criteria were used.

STATISTICAL ANALYSIS:

SPSS22.0 statistical software was used for statistical analysis of the data. The data are expressed as mean±standard deviation by t test, and the count data are expressed as rate (%) by the chi-square test. P<0.05 indicates that a difference was statistically significant.

Results

YEAR AND COUNTRY OF PUBLICATION:

For articles since 2001, our statistical analysis revealed no significant differences in the number of publications per year until 2013, and the number of published articles was small. However, the number of EIT articles rose sharply since 2014, and China and Germany have contributed a larger proportion, with over 100 articles/year published in 2019 and 2020 (Figure 1A). A statistical analysis showed that the largest number of articles were published by authors from China (n=254), followed by England (n=246), and Germany (n=244). The US ranked fourth highest in number of published articles, but they had the highest number of citations (n=7972) (Table 1). The number of collaborations by country was also counted, and the number of collaborations with Germany and China was greater than in other countries (Figure 1B). For more detailed data, see Figure 1 and Table 1.

AUTHORS AND INSTITUTIONS:

We ranked the number of posts and put together a tally of the information underlying these articles. Feng Fu from the Air Force Military Medical University (n=18) published the largest number of articles. The authors with the highest H-index among the top 20 were Inez Frerichs (H-index=11) from the University Medical Center Schleswig Holstein. More detailed data are presented in Table 2. The 20 most published institutions were also counted, and the 2 most published institutions were the University of London (n=90) and the University College London (n=87) from the UK, followed by the University of Kiel (n=70). The University of Eastern Finland (2575 citations; 39.62 citations per article) had the highest number of citations, with the third highest H-index of 27. This information is detailed in Table 3 and Figure 2.

SUBJECTS AND FUNDS:

The journal disciplines were analyzed by counting the journal disciplines in which EIT articles were published. EITs consistently appeared most frequently in engineering (29%), followed by physiology (10%) and biophysics (9%). Anesthesiology accounted for approximately 1% of this field during this period (Figure 3). Again, the top 10 organizations with the highest number of sponsored articles have been counted according to the number of sponsored articles. One sponsoring institution from China, 4 from the United States, and 5 from Europe were included. The funding agency with the most articles was the National Natural Science Foundation of China (n=168), followed by 2 sponsors from the USA, namely the National Institutes of Health (n=90) and the United States Department of Health and Human Services (n= 90). More detailed data can be found in Table 4.

JOURNAL ANALYSIS:

We then looked at the number of published EIT articles and ranked them by number (Table 5). The highest published journal was Physiological Measurement (n=228), followed by Inverse Problems (n=64), and IEEE Transactions on Medical Imaging (n=60). Among these journals, Intensive Care Medicine had the highest frequency of citations (76.14 citations per article) and the highest impact factor (IF=17.44). Figure 4 shows the results of a statistical analysis of the top 10 most published journals. Physiological Measurement accounted for a high percentage of the number of publications per year. Interestingly, from 2014 onwards, the number of journals receiving EIT articles and the number of articles published in these journals began to increase, like IEEE Transactions on Instrumentation and Measurement and IEEE Sensors Journal. One journal in anesthesiology, Acta Anaesthesiologica Scandinavica, was included.

CITATIONS AND CORRELATION ANALYSIS:

Each article has a different number of citations and we have summarized the most frequently cited articles over the last 20 years for comparison. These 20 articles included 14 basic studies, 1 retrospective clinical study, and 5 reviews (Figure 5A). The research content of the articles about new algorithms and protocols for EIT were classified as “EIT innovation articles” by us. EIT used to guide clinical treatment was classified as “clinical applications”. Fifteen articles described new ideas and proposed hypotheses for EIT, and 5 articles focused on the application of EIT to clinical work (Figure 5B). Interestingly, the top 2 highest-cited articles had the same title. The first was Electrical impedance tomography by Cheney, published in 1999 (cited frequency 719), which reviewed the reconstruction algorithm for EIT [19]. The other, published by Borcea published in 2002 (cited frequency 481), reviewed theoretical and numerical studies of the EIT inverse problem [20]. Third was Comparing reconstruction algorithms for electrical impedance, published by Yorkey in 1987 (cited frequency 401), which presented a new reconstruction algorithm [21]. Notably, Clinical recommendations when EIT is used in the chest, published by Frerichs in 2017, presented a consensus on the use of EIT for clinical mechanical ventilation and had the highest average annual citation count (78.5 citations per year on average) [22] (Table 6).

There was no correlation except for a significant correlation between year of publication and frequency of citations (r=0.3879; P=0.05) (Figure 5).

HOTSPOTS AND PUBLICATION TRENDS:

The classification of EIT articles into popular topics is based on the keywords of the article. The size of the circles in the graph and the thickness of the lines between them indicate how popular the topic is. All articles included in this period are categorized and summarized according to the first and last decade. For the first 10 years, the publications on EIT focused on innovation mechanism or system, as shown in the blue and green clusters (Figure 6A). In the latter decade, EIT articles began to become a more frequent and hot topic (Figure 6B). “Reconstruction or Image reconstruction” forms an important part of the green cluster. Meanwhile, the clinical application-related red cluster obviously increased, indicating the hotspots of EIT trends to clinical treatment. The key words “mechanical ventilation”, “PEEP”, “acute respiratory distress”, “obese patients”, “surgery”, or “general anesthesia” demonstrated the clinical interest of EIT.

Discussion

We searched the database and collected EIT articles from the 20 years after 2001, analyzing the types of articles and basic information. By conducting a correlation analysis, we found that the newer the year of the article, the higher the number of citations of the article, but the impact factor was not related to the number of citations of the article. Finally, by analyzing the hot trends of articles in the last 10 years, we found that EIT tends to move from basic research to clinical.

China contributed the highest number of articles and collaborated more with other countries. Among the authors with the highest number of articles, there were 6 from China, including the top author Feng Fu from the Air Force Military Medical University. The National Natural Science Foundation of China was the funding agency with the most articles. These results indicate that China was academically active in the field of EIT.

As a radiation-free non-invasive functional image monitoring technique, EIT provides lung ventilation, especially regional lung ventilation, and perfusion at the bedside [23]. Clinical needs have driven scientific and clinical interest in this advanced method. EIT assessment conveniently obtains unique clinical images without adverse effects compared with other similar techniques such as CT. For research hotspots, the co-existing keywords suggested that the earlier decade (2001 to 2010) was still the device development period, mainly focusing on image reconstruction, data analysis, and substitution algorithms. In the last decade, an increasing number of clinical trials in EIT applications have been published. EIT is widely used for acute respiratory distress syndrome (ARDS) or chronic obstructive pulmonary disease (COPD) patients in the intensive care unit (ICU), guiding mechanical ventilation therapy [24–27]. EIT is also a good choice due to its radiation-free features for neonates, infants, and children that require clinical interventions for lung function [28–30]. For patients under general anesthesia and undergoing surgery, EIT also provided excellent information for preoperative evaluation, perioperative personalized PEEP setup, and postoperative monitoring [31]. Several studies have titrated PEEP in obese patients to guide EIT during surgery to prevent postoperative atelectasis [32,33].

In the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic, EIT was used for the treatment of COVID-19-associated ARDS patients [34]. EIT is valuable as a bedside tool for evaluating ventilation distribution and perfusion and guiding PEEP titration [35,36]. Another case report suggested that in the time of COVID-19, EIT identified perfusion impairment that might require CT pulmonary angiography (CTPA) and evaluated the effect of therapy [37].

Some very influential articles are not counted in the list of high-frequency citations, probably because they were published very recently, for example, but that does not mean they are not important. Our search for EIT articles was limited to the Web of Science and did not include other databases [16], so some published articles may not have been collected by the search.

Conclusions

In conclusion, the hotspot and publication trends in the EIT from 2001 to 2020 were analyzed. This research clearly demonstrated that the study interest in EIT has increased yearly and has changed from technique development to clinical application. China contributed significantly to the field of EIT study, with the highest number of publications, the top author, and the funding agency with the most articles.

References

1. Adler A, Amyot R, Guardo R, Monitoring changes in lung air and liquid volumes with electrical impedance tomography: J Appl Physiol, 1997; 83(5); 1762-67

2. Adler A, Shinozuka N, Berthiaume Y, Electrical impedance tomography can monitor dynamic hyperinflation in dogs: J Appl Physiol, 1998; 84(2); 726-32

3. Barber DC, Brown BH, Applied potential tomography: J Phys E, 1984; 17(9); 723-33

4. Brown BH, Barber DC, Seagar AD, Applied potential tomography – possible clinical-applications: Clin Phys Physiol Meas, 1985; 6(2); 109-21

5. Long Y, Liu D-W, He H-W, Zhao Z-Q, Positive end-expiratory pressure titration after alveolar recruitment directed by electrical impedance tomography: Chin Med J (Eng), 2015; 128(11); 1421-27

6. Frerichs I, Hahn G, Hellige G, Gravity-dependent phenomena in lung ventilation determined by functional EIT: Physiol Meas, 1996; 17; A149-57

7. Frerichs I, Schiffmann H, Oehler R, Distribution of lung ventilation in spontaneously breathing neonates lying in different body positions: Intensive Care Med, 2003; 29(5); 787-94

8. Hinz J, Hahn G, Neumann P, End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change: Intensive Care Med, 2003; 29(1); 37-43

9. Kunst PWA, Bohm SH, de Anda GV, Regional pressure volume curves by electrical impedance tomography in a model of acute lung injury: Crit Care Med, 2000; 28(1); 178-83

10. Kunst PWA, de Anda GV, Bohm SH, Monitoring of recruitment and derecruitment by electrical impedance tomography in a model of acute lung injury: Cr Care Med, 2000; 28(12); 3891-95

11. Gattinoni L, Dandrea L, Pelosi P, Regional effects and mechanism of positive end-expiratory pressure in early adult respiratory-distress syndrome: JAMA, 1993; 269(16); 2122-27

12. Neumann P, Berglund JE, Andersson LG, Effects of inverse ratio ventilation and positive end-expiratory pressure in oleic acid-induced lung injury: Am J Respir Crit Care Med, 2000; 161(5); 1537-45

13. Neumann P, Berglund JE, Mondejar EF, Effect of different pressure levels on the dynamics of lung collapse and recruitment in oleic-acid-induced lung injury: Am J Respir Crit Care Med, 1998; 158(5); 1636-43

14. Genderingen HR, Vught AJ, Jansen JRC, Estimation of regional lung volume changes by electrical impedance tomography during a pressure-volume maneuver: Intensive Care Med, 2003; 29(2); 233-40

15. Bachmann MC, Morais C, Bugedo G, Electrical impedance tomography in acute respiratory distress syndrome: Critical Care, 2018; 22; 263

16. Karsten J, Grusnick C, Paarmann H, Positive end-expiratory pressure titration at bedside using electrical impedance tomography in post-operative cardiac surgery patients: Acta Anaesthesiol Scand, 2015; 59(6); 723-32

17. Gao H, Huang F-Y, Wang Z-P, Research trends of macrophage polarization: A bibliometric analysis: Chinese Med J (Engl), 2018; 131(24); 2968-75

18. Wang M, Xiao C, Ni P, Correlation of betel quid with oral cancer from 1998 to 2017: A study based on bibliometric analysis: Chin Med J (Engl), 2018; 131(16); 1975-82

19. Cheney M, Isaacson D, Newell JC, Electrical impedance tomography: Siam Review, 1999; 41(1); 85-101

20. Borcea L, Electrical impedance tomography: Inverse Problems, 2002; 18(6); R99-R136

21. Yorkey TJ, Webster JG, Tompkins WJ, Comparing reconstruction algorithms for electrical impedance tomography: IEEE Trans Biomed Eng, 1987; 34(11); 843-52

22. Frerichs I, Amato MBP, van Kaam AH, Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: Consensus statement of the TRanslational EIT developmeNt stuDy group: Thorax, 2017; 72(1); 83-93

23. Spinelli E, Mauri T, Fogagnolo A, Electrical impedance tomography in perioperative medicine: Careful respiratory monitoring for tailored interventions: BMC Anesthesiology, 2019; 19(1); 140

24. Vogt B, Pulletz S, Elke G, Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing: J Appl Physiol, 2012; 113(7); 1154-61

25. Vogt B, Zhao Z, Zabel P, Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease: Am J Physiol Lung Cell Mol Physiol, 2016; 311(1); L8-L19

26. Pulletz S, Kott M, Elke G, Dynamics of regional lung aeration determined by electrical impedance tomography in patients with acute respiratory distress syndrome: Multidiscipl Respir Med, 2012; 7(1); 44

27. Victorino JA, Borges JB, Okamoto VN, Imbalances in regional lung ventilation: Am J Respir Crit Care Med, 2004; 169(7); 791-800

28. Miedema M, de Jongh FH, Frerichs I, Changes in lung volume and ventilation during surfactant treatment in ventilated preterm infants: Am J Respir Crit Care Med, 2011; 184(1); 100-5

29. Wolf GK, Gómez-Laberge C, Kheir JN, Reversal of dependent lung collapse predicts response to lung recruitment in children with early acute lung injury: Pediatr Crit Care Med, 2012; 13(5); 509-15

30. van Veenendaal MB, Miedema M, de Jongh FHC, Effect of closed endotracheal suction in high-frequency ventilated premature infants measured with electrical impedance tomography: Intensive Care Med, 2009; 35(12); 2130

31. Girrbach F, Petroff D, Schulz S, Individualised positive end-expiratory pressure guided by electrical impedance tomography for robot-assisted laparoscopic radical prostatectomy: A prospective, randomised controlled clinical trial: Br J Anaesth, 2020; 125(3); 373-82

32. Nestler C, Simon P, Petroff D, Individualized positive end-expiratory pressure in obese patients during general anaesthesia: A randomized controlled clinical trial using electrical impedance tomography: Br J Anaesth, 2017; 119(6); 1194-205

33. Simon P, Girrbach F, Petroff D, Individualized versus fixed positive end-expiratory pressure for intraoperative mechanical ventilation in obese patients: A secondary analysis: Anesthesiology, 2021; 134(6); 887-900

34. Sella N, Pettenuzzo T, Della Paolera M, Two consecutive runs of veno-venous extracorporeal membrane oxygenation in a peripartum patient with COVID-19 acute respiratory distress syndrome: Case Rep Crit Care, 2021; 2021 2032197

35. Sella N, Zarantonello F, Andreatta G, Positive end-expiratory pressure titration in COVID-19 acute respiratory failure: electrical impedance tomography vs. PEEP/FiO2 tables: Cri Care, 2020; 24(1); 540

36. Morais CCA, Safaee Fakhr B, De Santis Santiago RR, Bedside electrical impedance tomography unveils respiratory “Chimera” in COVID-19: Am J Respir Crit Care Med, 2020; 203(1); 120-21

37. Safaee Fakhr B, Araujo Morais CC, De Santis Santiago RR, Bedside monitoring of lung perfusion by electrical impedance tomography in the time of COVID-19: Br J Anaesth, 2020; 125(5); e434-36

In Press

18 Mar 2024 : Clinical Research  

Sexual Dysfunction in Women After Tibial Fracture: A Retrospective Comparative Study

Med Sci Monit In Press; DOI: 10.12659/MSM.944136  

0:00

21 Feb 2024 : Clinical Research  

Potential Value of HSP90α in Prognosis of Triple-Negative Breast Cancer

Med Sci Monit In Press; DOI: 10.12659/MSM.943049  

22 Feb 2024 : Review article  

Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943168  

23 Feb 2024 : Clinical Research  

A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943732  

Most Viewed Current Articles

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750