Logo Medical Science Monitor Basic Research

Call: 1.631.470.9640
Mon-Fri 10 am - 2 pm EST

Contact Us

Logo Medical Science Monitor Basic Research Logo Medical Science Monitor Basic Research Logo Medical Science Monitor Basic Research

16 June 2004

Diagnostic imaging of carcinoid metastases to the abdomen and pelvis

Jarosław B Ćwikła, John R Buscombe, Martyn E Caplin, Anthony F Watkinson, Jerzy Walecki, Ewa Gorczyca-Wiśniewska, Andrew J W Hilson

Med Sci Monit 2004; 10(3): 9-16 :: ID: 11866

Abstract

Background:Functional and anatomical imaging methods are currently the standard approach to the evaluation of carcinoid tumor extent. Due to the nature of carcinoid tumors ,there is not a single imaging procedure that is sufficient to detect the malignancy. The aim of the study was to compare the value of CT, MR and functional imaging study with[sup]111[/sup] In-Octreotide (SRS) in carcinoid detection and evaluation of its extent as well as to work out the imaging studies diagnostic algorithm that could enhance diagnostic efficacy.Material/Methods: A total of 34 patients with carcinoid tumor confirmed clinically,biochemically and/or histopathologically were enrolled into the study. Computed tomography (CT) examinations of the abdomen and pelvis were performed before and after administration of a contrast medium, the triple-phase liver scanning included .Magnetic Resonance Imaging (MRI)of the liver was performed according to the standardized protocol before and after administration of a contrast medium .Planar scintigraphy with[sup]111[/sup] In Octreotide and SPECT were performed. In each case liver as well as lymph node metastases in the abdomen and pelvis weresearched for. All results were reviewed independently. Clinical picture at follow-up and further imaging and/or histological studies confirmed or excluded the diagnosis of the disease.Results: Twenty nine patients were diagnosed with carcinoid tumor. Liver metastases were found in 26 patients and lymph node metastases were detected in 18 of them. Complete diagnostic conformity as far as the diagnosis and extent of the disease are concerned was obtained only in 7 cases. Incorrect assessment of the disease extent was the source of discrepancy between the imaging studies results in most of the remaining 22 patients. The SRS and MR results of liver metastases detection were mostly consistent with one another. Both imaging modalities evaluated the extent of hepatic metastases incorrectly in 22%of the patients,as compared to 43% of the patients for CT. The highest proportion percentages of incorrect results of lymphatic involvement detection were 41%, 29%and 43%for MR, SRS and CT, respectively.Conclusions: The results of our study have indicated that application of a complex imaging algorithm enables higher accuracy of hepatic and lymph nodes metastases detection in carcinoid tumor patients. Combining the results of MR and SRS in evaluating the extent of the carcinoid disease seems to represent higher diagnostic value than relying on one of this method in combination with CT images.

Keywords: carotid and cerebral arteries, CTABACKGROUNDe-mail:[email protected] and cerebral arteries, CTA, atherosclerosis

0 Comments

Most Viewed Current Articles

13 Apr 2020 : Original article  

Outcome of 24 Weeks of Combined Schroth and Pilates Exercises on Cobb Angle, Angle of Trunk Rotation, Chest...

DOI :10.12659/MSMBR.920449

Med Sci Monit Basic Res 2020; 26:e920449

11 May 2020 : Original article  

Analysis of Psychological and Sleep Status and Exercise Rehabilitation of Front-Line Clinical Staff in the ...

DOI :10.12659/MSMBR.924085

Med Sci Monit Basic Res 2020; 26:e924085

05 Jan 2021 : Review article  

A Southeast Asian Perspective on the COVID-19 Pandemic: Hemoglobin E (HbE)-Trait Confers Resistance Against...

DOI :10.12659/MSMBR.929207

Med Sci Monit Basic Res 2021; 27:e929207

10 Aug 2020 : Clinical Research  

Effects of Cognitive Task Training on Dynamic Balance and Gait of Patients with Stroke: A Preliminary Rando...

DOI :10.12659/MSMBR.925264

Med Sci Monit Basic Res 2020; 26:e925264

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor Basic Research eISSN: 2325-4416
Medical Science Monitor Basic Research eISSN: 2325-4416