Critical evaluation of radiolabeled lymphocytes to detect acute renal transplant rejection in a large animal model.

John D. Petronis, Dilip S. Kittur, Chumpon Wilasrusmee

Med Sci Monit 2002; 8(12): BR515-520 :: ID: 4818

Abstract

BACKGROUND: Renal transplant rejection cannot be diagnosed with certainty by non-invasive techniques. These techniques lack the specificity to differentiate rejection from other causes of renal dysfunction such as ATN and calcineuria toxicity. Since rejection involves lymphocytes, which the other courses of dysfunction do not, radiolabeling lymphocytes is an attractive technique to diagnose rejection non-invasively. MATERIAL/METHODS: We report our experience with this technique in a pig model of renal transplantation. We studied two groups of pigs, one with renal autografts and the other with allografts. We optimized radiolabeling of lymphocytes and also the technology for detection of these lymphocytes. The uptake of the radiolabeled lymphocyte was compared between the two groups by surface detection and, at the end of the experiment, with scintigraphy of renal tissues. RESULTS: Despite adequate labeling and viability of lymphocytes, only 1-2% of injected lymphocytes 'homed' to the renal grafts. Furthermore, although the detection technology was optimized, a poor signal to noise ratio interfered with the detection of the labeled lymphocytes. Due to these problems rejection could not be differentiated from ATN in this model. CONCLUSIONS: We conclude that increasing the specific activity of the lymphocytes and improving the signal to noise ratio will enhance the specificity and sensitivity of this technique and facilitate non-invasive diagnosis of rejection.

Keywords: Graft Rejection - radionuclide imaging, Kidney Transplantation - radionuclide imaging, Organometallic Compounds - diagnostic use, Oxyquinoline - analogs & derivatives, Oxyquinoline - diagnostic use

Comments

Most Viewed Current Articles

13 Apr 2020 : Original article  

Outcome of 24 Weeks of Combined Schroth and Pilates Exercises on Cobb Angle, Angle of Trunk Rotation, Chest...

DOI :10.12659/MSMBR.920449

Med Sci Monit Basic Res 2020; 26:e920449

11 May 2020 : Original article  

Analysis of Psychological and Sleep Status and Exercise Rehabilitation of Front-Line Clinical Staff in the ...

DOI :10.12659/MSMBR.924085

Med Sci Monit Basic Res 2020; 26:e924085

05 Jan 2021 : Review article  

A Southeast Asian Perspective on the COVID-19 Pandemic: Hemoglobin E (HbE)-Trait Confers Resistance Against...

DOI :10.12659/MSMBR.929207

Med Sci Monit Basic Res 2021; 27:e929207

10 Aug 2020 : Clinical Research  

Effects of Cognitive Task Training on Dynamic Balance and Gait of Patients with Stroke: A Preliminary Rando...

DOI :10.12659/MSMBR.925264

Med Sci Monit Basic Res 2020; 26:e925264

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor Basic Research eISSN: 2325-4416
Medical Science Monitor Basic Research eISSN: 2325-4416