Logo Medical Science Monitor Basic Research

Call: 1.631.470.9640
Mon-Fri 10 am - 2 pm EST

Contact Us

Logo Medical Science Monitor Basic Research Logo Medical Science Monitor Basic Research Logo Medical Science Monitor Basic Research

20 May 2010

Patient specific implants, designed using Rapid Prototyping and diagnostic imaging, for the repair of orbital fractures

Marcin T. Elgalal, Marcin Kozakiewicz, Piotr Loba, Bogdan Walkowiak, Marek Olszycki, Ludomir Stefańczyk

Med Sci Monit 2010; 16(1): 75-79 :: ID: 880587

Abstract

Background: Craniofacial trauma affects orbital structures in approximately 40% of all cases. Over the years, there has been a marked increase in applying preformed implants for the reconstruction of orbital fractures. Such implants significantly shorten operating times and decrease trauma to intraorbital structures during surgery. This study sought to create anatomic models of the bony orbit based on MSCT images, and use them as templates to form titanium mesh into custom, patient-specific implants for the reconstruction of orbital wall defects. Furthermore, the aim was to compare this new technique with a conventional method of treatment.
Material/Methods: A total of 30 patients with facial trauma and orbital fractures were included and divided into 2 groups. The first group of 15 subjects was treated with custom implants formed before surgery. The second group of 15 patients had been previously treated using a conventional method of manual implant formation during surgery. Both groups underwent ophthalmic evaluation and were statistically compared.
Results: Significant improvement in all cases was seen after surgery based on ophthalmic examination. There is a statistically significant superiority of RP (rapid prototyping) treatment method over CM (conventional method) when the area of diplopic vision (binocular single vision loss) and upgaze VVD (vertical visual disparity) reduction are considered.
Conclusions: With this new method of treatment, it is possible to use MSCT imaging to create accurate, individual implants. Such implants allow for precise reconstruction of tissue defects and better outcome.

Keywords: computerized tomography, rapid prototyping, computer models , Orbital Fractures, Orbital Implants

Comments

Most Viewed Current Articles

31 Dec 1969 : Original article  

Outcome of 24 Weeks of Combined Schroth and Pilates Exercises on Cobb Angle, Angle of Trunk Rotation, Chest...

DOI :10.12659/MSMBR.920449

Med Sci Monit Basic Res 2020; 26:e920449

31 Dec 1969 : Original article  

Analysis of Psychological and Sleep Status and Exercise Rehabilitation of Front-Line Clinical Staff in the ...

DOI :10.12659/MSMBR.924085

Med Sci Monit Basic Res 2020; 26:e924085

31 Dec 1969 : Review article  

A Southeast Asian Perspective on the COVID-19 Pandemic: Hemoglobin E (HbE)-Trait Confers Resistance Against...

DOI :10.12659/MSMBR.929207

Med Sci Monit Basic Res 2021; 27:e929207

31 Dec 1969 : Clinical Research  

Effects of Cognitive Task Training on Dynamic Balance and Gait of Patients with Stroke: A Preliminary Rando...

DOI :10.12659/MSMBR.925264

Med Sci Monit Basic Res 2020; 26:e925264

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor Basic Research eISSN: 2325-4416
Medical Science Monitor Basic Research eISSN: 2325-4416