Logo Medical Science Monitor Basic Research

Call: 1.631.470.9640
Mon-Fri 10 am - 2 pm EST

Contact Us

Logo Medical Science Monitor Basic Research Logo Medical Science Monitor Basic Research Logo Medical Science Monitor Basic Research

08 March 2014 : Research paper  

The pleth variability index as an indicator of the central extracellular fluid volume in mechanically ventilated patients after anesthesia induction: Comparison with initial distribution volume of glucose

Wenqing LuBCF, Jing DongCF, Zifeng XuB, Hao ShenBC, Jijian ZhengADEG

DOI: 10.12659/MSM.890073

Med Sci Monit 2014; 20:386-392

Abstract

BACKGROUND: The pleth variability index (PVI) has been demonstrated to be a useful, noninvasive indicator of continuous fluid responsiveness. Whether PVI can be used to assess the changes of intravascular volume status remains to be elucidated.

MATERIAL AND METHODS: Using correlation analysis and receiver operating characteristic (ROC) curves, we sought a correlation between PVI and the initial distribution volume of glucose (IDVG), evaluating PVI as an indicator of the central extracellular fluid volume after anesthesia induction in patients undergoing elective abdominal surgery.

RESULTS: Strong negative correlations existed between IDVG and PVI (r=–0.72), IDVG, and pulse pressure variation (PPV) (r=–0.73), and between IDVG and systolic pressure variation (SPV) (r=–0.53), P<0.01. Strong positive correlations existed between PPV and PVI (r=0.66), PVI and SPV (r=0.49), and between PPV and SPV (r=0.59), P<0.01. The areas under the ROC curve of IDVG, PVI, and SPV were significantly different from the area under a reference line. The optimal cutoff values (followed by sensitivity and specificity in parentheses) comparable to PPV over 11% as the threshold of hypovolemia were IDVG 94.5 mL/kg (75%, 100%), PVI 13% (91.7%, 77.8%), and SPV 7% (41.7%, 100%).

CONCLUSIONS: Our results show that strong correlations exist among IDVG, PVI, PPV, and SPV in the evaluation of volemia. PVI can serve as a useful, noninvasive indicator of continuous central extracellular fluid volume for those patients not requiring invasive hemodynamic monitoring, but needs attention to changes in intravascular volume status for optimal fluid management.

Keywords: Anesthesia, General, Extracellular Fluid, Respiration, Artificial, Administration, Intravenous, Blood Glucose - metabolism, Blood Pressure, Demography, Extracellular Fluid - metabolism, Monitoring, Physiologic, Plethysmography, Pulse, ROC Curve, Surgical Procedures, Elective, Systole

0 Comments

Most Viewed Current Articles

13 Apr 2020 : Original article  

Outcome of 24 Weeks of Combined Schroth and Pilates Exercises on Cobb Angle, Angle of Trunk Rotation, Chest...

DOI :10.12659/MSMBR.920449

Med Sci Monit Basic Res 2020; 26:e920449

11 May 2020 : Original article  

Analysis of Psychological and Sleep Status and Exercise Rehabilitation of Front-Line Clinical Staff in the ...

DOI :10.12659/MSMBR.924085

Med Sci Monit Basic Res 2020; 26:e924085

05 Jan 2021 : Review article  

A Southeast Asian Perspective on the COVID-19 Pandemic: Hemoglobin E (HbE)-Trait Confers Resistance Against...

DOI :10.12659/MSMBR.929207

Med Sci Monit Basic Res 2021; 27:e929207

10 Aug 2020 : Clinical Research  

Effects of Cognitive Task Training on Dynamic Balance and Gait of Patients with Stroke: A Preliminary Rando...

DOI :10.12659/MSMBR.925264

Med Sci Monit Basic Res 2020; 26:e925264

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.