Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

01 August 2016 : Clinical Research  

Relationship Between Respiratory Dynamics and Body Mass Index in Patients Undergoing General Anesthesia with Laryngeal Mask Airway (LMA) and Comparison Between Lithotomy and Supine Positions

Xiao ZhaoBCDEF, Shiwei HuangACF, Zhaomin WangBC, Lianhua ChenACDEG, Shitong LiADEF

DOI: 10.12659/MSM.897086

Med Sci Monit 2016; 22:2706-2713

Abstract

BACKGROUND: This study aimed to compare respiratory dynamics in patients undergoing general anesthesia with a laryngeal mask airway (LMA) in lithotomy and supine positions and to validate the impact of operational position on effectiveness of LMA ventilation.

MATERIAL AND METHODS: A total of 90 patients (age range, 18–65 years) who underwent general anesthesia were selected and divided into supine position (SP group) and lithotomy position groups (LP group). Vital signs and respiratory dynamic parameters of the 2 groups were measured at different time points and after implantation of an LMA. The arterial blood gas was monitored at 15 min after induction. The intraoperative changes of hemodynamic indexes and postoperative adverse reactions of LMA were recorded. The possible correlation between body mass index (BMI) and respiratory dynamic indexes was analyzed.

RESULTS: With prolonged duration of the operation, the inspiratory plateau pressure (Pplat), inspiratory resistance (RI), and work of breathing (WOB) gradually increased, while chest-lung compliance (Compl) and partial pressure of carbon dioxide in end-expiratory gas (PetCO2) gradually decreased (all P value <0.05). The mean airway pressure (Pmean), Pplat, and expiratory resistance (Re) in the LP group were significantly higher than in the SP group (P<0.05), while the peak inspiratory flow (FImax), peak expiratory flow (FEmax), WOB, and Compl in the LP group were significantly lower than in the SP group (P<0.05). BMI was positively correlated with peak airway pressure (PIP/Ppeak), Pplat, and airway resistance (Raw) and was negatively correlated with Compl; the differences among patients in lithotomy position were more remarkable (P<0.05).

CONCLUSIONS: The inspiratory plateau pressure and airway resistance increased with prolonged duration of the operation, accompanied by decreased chest-lung compliance. Peak airway pressure and airway resistance were positively correlated with BMI, and chest-lung compliance was negatively correlated with BMI. Changes among patients in lithotomy position were more remarkable than those in supine position.

Keywords: Anesthesia, General - methods, Adolescent, Blood Gas Analysis, Body Mass Index, Hemodynamics, Intubation, Intratracheal, Laryngeal Masks, Respiratory Rate

Add Comment 0 Comments

Editorial

01 April 2024 : Editorial  

Editorial: Forty Years of Waiting for Prevention and Cure of HIV Infection – Ongoing Challenges and Hopes for Vaccine Development and Overcoming Antiretroviral Drug Resistance

Dinah V. Parums

DOI: 10.12659/MSM.944600

Med Sci Monit 2024; 30:e944600

0:00

In Press

06 Mar 2024 : Clinical Research  

Comparison of Outcomes between Single-Level and Double-Level Corpectomy in Thoracolumbar Reconstruction: A ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943797  

21 Mar 2024 : Meta-Analysis  

Economic Evaluation of COVID-19 Screening Tests and Surveillance Strategies in Low-Income, Middle-Income, a...

Med Sci Monit In Press; DOI: 10.12659/MSM.943863  

10 Apr 2024 : Clinical Research  

Predicting Acute Cardiovascular Complications in COVID-19: Insights from a Specialized Cardiac Referral Dep...

Med Sci Monit In Press; DOI: 10.12659/MSM.942612  

06 Mar 2024 : Clinical Research  

Enhanced Surgical Outcomes of Popliteal Cyst Excision: A Retrospective Study Comparing Arthroscopic Debride...

Med Sci Monit In Press; DOI: 10.12659/MSM.941102  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750