Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

08 June 2017 : Clinical Research  

Are Sutureless Aortic Valves Suitable for Severe High-Risk Patients Suffering from Active Infective Aortic Valve Endocarditis?

Alexander Weymann1ABCDEFG*, Johanna Konertz1ABCDEFG, Michael Laule2ABCDEFG, Karl Stangl2ABCDEFG, Pascal M. Dohmen13ABCDEFG

DOI: 10.12659/MSM.902785

Med Sci Monit 2017; 23:2782-2787

Abstract

BACKGROUND: Sutureless aortic valves were introduced to facilitate minimally invasive aortic valve surgery. Since sutureless aortic valves are a feasible procedure, we evaluated if any benefits could be identified in severe high-risk patients with active infective endocarditis of the aortic valve.

MATERIAL AND METHODS: Between April 2014 and April 2015, a total of 42 patients received a sutureless Perceval® aortic valve (Sorin Biomedica Cardio Srl, Saluggia, Italy) for different indications. Nine of these patients (median age 71 years, range 47–83 years) suffered from active infective endocarditis, including four patients with prosthetic aortic valve endocarditis. Five patients underwent prior cardiac surgery, including transcatheter aortic valve implantation (TAVI). The median EuroSCORE II was 29.5% (range 16.8–87.7%). Post-operatively, data regarding mortality, operative results, and early operative morbidity were collected.

RESULTS: There were no cases of 30-day mortality. Four patients needed abscess closure with pericardium. Three patients underwent left atrial appendix closure: one left ventricular thrombectomy, one bypass grafting, and one arch replacement. Median aortic cross-clamp and cardiopulmonary bypass time was 35 minutes (range 26–88 minutes) and 52 minutes (range 40–133 minutes), respectively. The median intubation time was 14 hours (range 1–9 hours). In these high-risk patients, no postoperative morbidity was found except for one re-intubation due to extensive delirium and one re-exploration. No pacemaker implantation was needed. Echocardiographic evaluation showed no central or para-valvular regurgitation, and a median discharge mean gradient of 5.5 mm Hg (range 2.5–10.0 mm Hg).

CONCLUSIONS: Sutureless aortic valve replacement in very high-risk patients suffering from active infection endocarditis seems to be an option with limited morbidity and appropriate echocardiographic results, however, further studies are needed.

Keywords: Cardiac Surgical Procedures, Endocarditis, Bacterial, Heart Valve Prosthesis Implantation

Add Comment 0 Comments

Editorial

01 March 2024 : Editorial  

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and Transfusion-Dependent β-Thalassemia

Dinah V. Parums

DOI: 10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

In Press

21 Feb 2024 : Clinical Research  

Potential Value of HSP90α in Prognosis of Triple-Negative Breast Cancer

Med Sci Monit In Press; DOI: 10.12659/MSM.943049  

22 Feb 2024 : Review article  

Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943168  

23 Feb 2024 : Clinical Research  

A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943732  

26 Feb 2024 : Clinical Research  

Predictive Value of Combined HbA1c and Neutrophil-to-Lymphocyte Ratio for Diabetic Peripheral Neuropathy in...

Med Sci Monit In Press; DOI: 10.12659/MSM.942509  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750