Comparison of Commercially Available Blood Collection Tubes Containing Sodium Citrate and Hirudin in Platelet Aggregation Testing

Walter J. Janse van Rensburg1ACDEFG*, Patricia van der Merwe1BD

DOI: 10.12659/MSMBR.905246

Med Sci Monit Basic Res 2017; 23:264-269

Abstract

BACKGROUND: Platelet reactivity assessment is an important tool in both the causal determination of bleeding diathesis as well as in the evaluation of the efficacy of anti-platelet therapy in patients at risk of thrombosis. Sodium citrate is the most widely used anticoagulant for hemostasis investigations. However, some doubt exists over the suitability of sodium citrate in platelet function testing. Hirudin has been suggested as a superior replacement. Nevertheless, only 1 study compared citrated and hirudin treated samples with light transmission aggregometry. Therefore, limited evidence exists to conclusively prove the supremacy of hirudin over sodium citrate in light transmission aggregometry. The aim of our study was to compare citrated and hirudin treated samples, collected in commercially available blood collection tubes, using the 5 most common agonists, with light transmission aggregometry.

MATERIAL AND METHODS: Blood was obtained from 20 healthy volunteers. Platelet counts were performed on platelet-rich plasma. Light transmission aggregometry was performed within 4 h of sample collection using ADP, collagen, arachidonic acid, epinephrine, and ristocetin as agonists.

RESULTS: Platelet counts for the respective anticoagulants did not differ significantly. ADP-induced aggregation was comparable between the samples. However, among all the agonists, hirudin-treated platelets had significantly weaker aggregatory responses.

CONCLUSIONS: Commercially available sodium citrate should remain the anticoagulant of choice for routine platelet function testing in our setting. However, the time limitation associated with the use of sodium citrate in platelet function testing remains a concern. Thus, alternative anticoagulants should still be explored.

Keywords: Anticoagulants, Hirudins, Platelet Function Tests

Add Comment 0 Comments

In Press

Clinical Research  

Questionnaire-Based Study of 392 Women in Abbottabad, Pakistan, to Evaluate the Types of Cosmetic Products ...

Med Sci Monit Basic Res In Press; DOI:  

Most Viewed Current Articles

15 Jun 2022 : Clinical Research  

Evaluation of Apical Leakage After Root Canal Obturation with Glass Ionomer, Resin, and Zinc Oxide Eugenol ...

DOI :10.12659/MSMBR.936675

Med Sci Monit Basic Res 2022; 28:e936675

07 Jul 2022 : Laboratory Research  

Cytotoxicity, Apoptosis, Migration Inhibition, and Autophagy-Induced by Crude Ricin from Ricinus communis S...

DOI :10.12659/MSMBR.936683

Med Sci Monit Basic Res 2022; 28:e936683

01 Jun 2022 : Laboratory Research  

Comparison of Sealing Abilities Among Zinc Oxide Eugenol Root-Canal Filling Cement, Antibacterial Biocerami...

DOI :10.12659/MSMBR.936319

Med Sci Monit Basic Res 2022; 28:e936319

17 Jan 2022 : Clinical Research  

Anodal Transcranial Direct Current Stimulation (tDCS) Over the Primary Motor Cortex (M1) Enhances Motor Res...

DOI :10.12659/MSMBR.934180

Med Sci Monit Basic Res 2022; 28:e934180

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.