05 February 2019 : Clinical Research
Peripapillary Retinal Nerve Fiber Layer Thickness in Patients with Alzheimer’s Disease: A Comparison of Eyes of Patients with Alzheimer’s Disease, Primary Open-Angle Glaucoma, and Preperimetric Glaucoma and Healthy Controls
Przemysław Zabel12ABDEF*, Jakub J. Kałużny12ADE, Monika Wiłkość-Dębczyńska34CE, Martyna Gębska-Tołoczko1BF, Karolina Suwała1BF, Robert Kucharski5BD, Aleksander Araszkiewicz4ADOI: 10.12659/MSM.914889
Med Sci Monit 2019; 25:1001-1008
Abstract
BACKGROUND: The aim of this study was to assess and compare peripapillary retinal nerve fiber layer (RNFL) thickness in patients with Alzheimer’s disease (AD), primary open-angle glaucoma (POAG), preperimetric glaucoma (PPG), and healthy controls with the use of Spectral Domain Optical Coherence Tomography (SD-OCT).
MATERIAL AND METHODS: Thirty patients with AD, 30 patients with POAG, 30 patients with PPG, and 30 healthy controls were enrolled in this cross-sectional study. Only 1 randomly selected eye of each patient was analyzed. Every subject underwent a thorough ophthalmological examination and OCT of the optic disc. The peripapillary RNFL thickness in each of the 6 sectors and globally was analyzed.
RESULTS: The RNFL was thinnest in patients with POAG. The mean RNFL thickness value was 60.97±12.97 µm and it was significantly lower than in healthy controls (106.30±8.95 µm), patients with PPG (93.20±12.04 µm), and AD patients (95.73±13.52 µm). Mean RNFL thickness in patients with AD was significantly lower when compared to healthy controls, and was higher compared to eyes with POAG, while there were no significant differences compared to patients with PPG.
CONCLUSIONS: Neuronal damage in the central nervous system (CNS) also affects to retinal axons. A major problem is to distinguish the cause for a moderate decrease in the RNFL thickness. This is particularly true for patients with glaucoma who have not been diagnosed with changes in the visual field. It is not possible to distinguish the cause of a mild decrease in the RNFL thickness based on the SD-OCT. This may result in misdiagnosis of glaucoma, unnecessary use of anti-glaucoma eye drops, and a delayed diagnosis of AD.
Keywords: Alzheimer Disease, Glaucoma, Open-Angle, Tomography, Optical Coherence, Aged, Aged, 80 and over, Case-Control Studies, Cross-Sectional Studies, Glaucoma, Intraocular Pressure, Middle Aged, Nerve Fibers, ROC Curve, Retina, Retinal Ganglion Cells, Retinal Neurons, Visual Fields
Most Viewed Current Articles
13 Apr 2020 : Original article
Outcome of 24 Weeks of Combined Schroth and Pilates Exercises on Cobb Angle, Angle of Trunk Rotation, Chest...DOI :10.12659/MSMBR.920449
Med Sci Monit Basic Res 2020; 26:e920449
11 May 2020 : Original article
Analysis of Psychological and Sleep Status and Exercise Rehabilitation of Front-Line Clinical Staff in the ...DOI :10.12659/MSMBR.924085
Med Sci Monit Basic Res 2020; 26:e924085
05 Jan 2021 : Review article
A Southeast Asian Perspective on the COVID-19 Pandemic: Hemoglobin E (HbE)-Trait Confers Resistance Against...DOI :10.12659/MSMBR.929207
Med Sci Monit Basic Res 2021; 27:e929207
10 Aug 2020 : Clinical Research
Effects of Cognitive Task Training on Dynamic Balance and Gait of Patients with Stroke: A Preliminary Rando...DOI :10.12659/MSMBR.925264
Med Sci Monit Basic Res 2020; 26:e925264