Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

01 July 2008

CobraPLA Insertion by anesthetists and non-anesthetists wearing unconventional protective gear: a prospective study in humans

Ron Ben-AbrahamE, Ron FlaishonB, Alexander SotmanB, Perla EksteinF, Tiberiu EzriD, Daniel OgorekC, Avi A WeinbroumA

Med Sci Monit 2008; 14(7): PI13-18 :: ID: 863650

Abstract

Background
The threat of a mass casualty unconventional attack has challenged the medical community to devise means for providing rapid and reliable emergent airway control under chaotic conditions by inexperienced medical personnel dressed in self protective gear. Since endotracheal intubation may not be feasible under those conditions, other extraglottic devices should be considered. We assessed the performance of anesthesia and non-anesthesia residents in inserting the CobraPLA, a supraglottic airway device, on consecutive anesthetized patients, to assess its potential use under simulated conditions.
Material and Method
Anesthesia and non-anesthesia residents wearing either surgical scrubs or complete anti-chemical gear inserted the CobraPLA in anesthetized patients. If post-trial positive pressure ventilation via the CobraPLA was unsuccessful, an LMA or endotracheal tube was inserted in its stead.
Results
It took anesthesia residents 57+/-23 sec and 43+/-13 sec (P<0.05) to place the CobraPLA while wearing anti-chemical gear and surgical scrubs, respectively. Non-anesthesia residents wearing anti-chemical gear performed worse than anesthetists in their first insertion (73+/-9 sec, P<0.05), but after the brief training period they performed as well as their colleagues anesthetists (58+/-10 sec, P=NS). Post-trial, twenty-one CobraPLA (42%) leaked, preventing adequate positive-pressure ventilation: 13 devices (26% of the total) required replacements.
Conclusions
Anti-chemical protective gear slowed the insertion of the CobraPLA by anesthetists, and more so by other residents inexperienced in airway management. In 26% of the cases CobraPLA was inadequate for positive pressure ventilation.

Keywords: Protective Clothing, Prospective Studies, Physicians, Laryngeal Masks, Intubation, Intratracheal - instrumentation, Internship and Residency, Time Factors, Demography, Anesthesiology

Add Comment 0 Comments

Editorial

01 April 2024 : Editorial  

Editorial: Forty Years of Waiting for Prevention and Cure of HIV Infection – Ongoing Challenges and Hopes for Vaccine Development and Overcoming Antiretroviral Drug Resistance

Dinah V. Parums

DOI: 10.12659/MSM.944600

Med Sci Monit 2024; 30:e944600

0:00

In Press

05 Mar 2024 : Clinical Research  

Effects of Thermal Insulation on Recovery and Comfort of Patients Undergoing Holmium Laser Lithotripsy

Med Sci Monit In Press; DOI: 10.12659/MSM.942836  

05 Mar 2024 : Clinical Research  

Role of Critical Shoulder Angle in Degenerative Type Rotator Cuff Tears: A Turkish Cohort Study

Med Sci Monit In Press; DOI: 10.12659/MSM.943703  

06 Mar 2024 : Clinical Research  

Comparison of Outcomes between Single-Level and Double-Level Corpectomy in Thoracolumbar Reconstruction: A ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943797  

21 Mar 2024 : Meta-Analysis  

Economic Evaluation of COVID-19 Screening Tests and Surveillance Strategies in Low-Income, Middle-Income, a...

Med Sci Monit In Press; DOI: 10.12659/MSM.943863  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750