17 October 2016 : Clinical Research
Treatment of Unstable Posterior Pelvic Ring Fracture with Pedicle Screw-Rod Fixator Versus Locking Compression Plate: A Comparative Study
Chun BiABE, Qiugen WangBDG, Christopher NagelliACD, Jianhong WuCFG, Qian WangBF, Jiandong WangADGDOI: 10.12659/MSM.900673
Med Sci Monit 2016; 22:3764-3770
Abstract
BACKGROUND: The aim of this study was to assess the clinical results of treatment for unstable posterior pelvic fractures using a pedicle screw-rod fixator compared to use of a locking compression plate.
MATERIAL AND METHODS: A retrospective study was performed between June 2010 and May 2014 and the data were collected from 46 patients with unstable posterior pelvic ring fractures. All patients were treated using either a pedicle screw-rod fixator (study group, 24 patients) or locking compression plate (control group, 22 patients). In these patients, causes of injury included traffic accidents (n=27), fall from height (n=12), and crushing accidents (n=7). The quality of reduction and radiological grading were assessed. Clinical assessments included the operation time, times of X-ray exposures, bleeding volume during operation, incision length, and Majeed postoperative functional evaluation.
RESULTS: No iatrogenic neurovascular injuries occurred during the operations in these 2 groups. The average follow-up time was 24.5 months. All fractures were healed. The significant differences (P<0.05) between the 2 groups were operation duration, size of incision, and intraoperative bleeding volume. Statistically significant differences in the Majeed postoperative functional evaluation and times of X-ray exposures were not found between the 2 groups.
CONCLUSIONS: Similar clinical effects were achieved in treating the posterior pelvic ring fractures using the pedicle screw-rod fixator and the locking compression plate. However, the pedicle screw-rod fixator has the advantages of smaller incision, shorter duration of the operation, and less bleeding volume compared to using the locking compression plate.
Keywords: Fractures, Bone, Internal Fixators, Pelvic Bones
Editorial
01 March 2024 : Editorial
Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and Transfusion-Dependent β-ThalassemiaDOI: 10.12659/MSM.944204
Med Sci Monit 2024; 30:e944204
In Press
21 Feb 2024 : Clinical Research
Potential Value of HSP90α in Prognosis of Triple-Negative Breast CancerMed Sci Monit In Press; DOI: 10.12659/MSM.943049
22 Feb 2024 : Review article
Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...Med Sci Monit In Press; DOI: 10.12659/MSM.943168
23 Feb 2024 : Clinical Research
A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...Med Sci Monit In Press; DOI: 10.12659/MSM.943732
26 Feb 2024 : Clinical Research
Predictive Value of Combined HbA1c and Neutrophil-to-Lymphocyte Ratio for Diabetic Peripheral Neuropathy in...Med Sci Monit In Press; DOI: 10.12659/MSM.942509
Most Viewed Current Articles
17 Jan 2024 : Review article
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
16 May 2023 : Clinical Research
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
14 Dec 2022 : Clinical Research
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
01 Jan 2022 : Editorial
Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...DOI :10.12659/MSM.935952
Med Sci Monit 2022; 28:e935952