Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

28 January 2015 : Clinical Research  

A New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory

Rafał Nikodem WlazełABCDEFG, Jarosław KasprzakCDE, Marek ParadowskiADFG

DOI: 10.12659/MSM.892033

Med Sci Monit 2015; 21:338-344

Abstract

BACKGROUND: ecent guidelines recommended by ESC, ACC, AHA, and WHF concerning biomarkers of myocardial necrosis also apply to the work of clinical laboratories. Methodological modification for tests used in determining cardiac biomarkers reduced the time of the analytical procedure to 9 min (STAT version of the tests). We decided to determine and compare analytical quality of the tests in standard and STAT versions for determining serum level: troponin T, MB isoenzyme of creatine kinase, and myoglobin, as well as to verify whether the TnThs STAT test meets the following requirements: CV <10% at the level close to diagnostic, equal to the 99th percentile of reference population, and turnaround time <60 min.

MATERIAL AND METHODS: We evaluated real precision and accuracy for both standard and STAT versions of tests as well as the correlation of results of physiological and pathological levels. Additionally, observations of turnaround time were made.

RESULTS: Calculated values of total errors did not exceed the recommended acceptable total error (<20%). Comparable precision of the 2 measurement methods (CV=3.07%) was obtained. A strong correlation (R>0.99) between both variants of tests for all the parameters was confirmed. Thanks to the application of new reagent kit, the percentage of results with turnaround time <60 min increased from 40% to 75% (n=115; p=0.000008).

CONCLUSIONS: The new generation of STAT cardiac biomarkers has high analytical quality and meets international precision requirements. It guarantees high analytical and clinical reliability of results. Use of the STAT version of biomarkers contributes to a significant decrease in turnaround time and allows obtaining a good result of an analysis.

Keywords: Acute Coronary Syndrome - diagnosis, Biological Markers - metabolism, Clinical Laboratory Techniques, Creatine Kinase, MB Form - chemistry, Isoenzymes - chemistry, Myocardium - pathology, Myoglobin - chemistry, Necrosis - pathology, Reproducibility of Results, Time Factors, Troponin T - chemistry

Add Comment 0 Comments

Editorial

01 May 2024 : Editorial  

Editorial: First Regulatory Approval for Adoptive Cell Therapy with Autologous Tumor-Infiltrating Lymphocytes (TILs) – Lifileucel (Amtagvi)

Dinah V. Parums

DOI: 10.12659/MSM.944927

Med Sci Monit 2024; 30:e944927

In Press

11 Mar 2024 : Clinical Research  

Enhancement of Frozen-Thawed Human Sperm Quality with Zinc as a Cryoprotective Additive

Med Sci Monit In Press; DOI: 10.12659/MSM.942946  

0:00

12 Mar 2024 : Database Analysis  

Risk Factors of Age-Related Macular Degeneration in a Population-Based Study: Results from SHIP-TREND-1 (St...

Med Sci Monit In Press; DOI: 10.12659/MSM.943140  

0:00

12 Mar 2024 : Clinical Research  

Preoperative Blood Transfusion Requirements for Hemorrhoidal Severe Anemia: A Retrospective Study of 128 Pa...

Med Sci Monit In Press; DOI: 10.12659/MSM.943126  

0:00

12 Mar 2024 : Clinical Research  

Tissue Inhibitors of Metalloproteinase 1 (TIMP-1) and 3 (TIMP-3) as New Markers of Acute Kidney Injury Afte...

Med Sci Monit In Press; DOI: 10.12659/MSM.943500  

0:00

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750