09 September 2017 : Clinical Research
Low-Dose Scanning Technology Combined with Low-Concentration Contrast Material in Renal Computed Tomography Angiography (CTA): A Preliminary Study
Sulan Liu1AE, Wei Li1AE, Hao Shi1BE, Huaqiang Sheng1BE, Jingli Fan2DF, Jingzhen He3DF, Hongjun Sun1AFG*DOI: 10.12659/MSM.902917
Med Sci Monit 2017; 23:4351-4359
Abstract
BACKGROUND: This study is to investigate the feasibility of low iodine concentration contrast material (CM) combined with low tube voltage and adaptive statistical iterative reconstruction (ASIR) in renal computed tomography angiography (CTA).
MATERIAL AND METHODS: A total of 136 patients were enrolled in this prospective trial, and randomly divided into two groups: group A (n=68) and group B (n=68). Group A received 120-kVp and iopromide (370 mg/mL) with filtered back projection (FBP) reconstruction, and group B received 100-kVp and iodixanol (270 mg/mL) with ASIR 40% (ASIR40). An equal iodine dose (300 mg/kg body weight) and the same iodine delivery rate (1,500 mg I/s) were given to all patients. Density, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured, and the image quality and visualization of renal arteries were scored. Dose-length product (DLP) and CT dose index volume (CTDIvol) were recorded, and effective doses (ED) were calculated.
RESULTS: There was no significant difference in image noise between groups A and B (p>0.05). The vessel attenuation, SNR, and CNR were significantly higher in group B than group A (all p<0.05). The subjective image quality and visualization of renal artery branches were similar in these two groups (p>0.05). Compared with group A, the CTDIvol, DLP, and ED in group B were decreased by 38.58%, 37.24%, and 37.24%, respectively (p=0.000).
CONCLUSIONS: Compared with 120-kVp with FBP reconstruction, the protocol of 100-kVp with ASIRP40 reconstruction provided high-quality renal CTA results, which allowed for reduced iodine concentration and decreased radiation dose.
Keywords: Angiography, Four-Dimensional Computed Tomography, Microscopy, Acoustic
Editorial
01 May 2024 : Editorial
Editorial: First Regulatory Approval for Adoptive Cell Therapy with Autologous Tumor-Infiltrating Lymphocytes (TILs) – Lifileucel (Amtagvi)DOI: 10.12659/MSM.944927
Med Sci Monit 2024; 30:e944927
In Press
11 Mar 2024 : Clinical Research
Enhancement of Frozen-Thawed Human Sperm Quality with Zinc as a Cryoprotective AdditiveMed Sci Monit In Press; DOI: 10.12659/MSM.942946
12 Mar 2024 : Database Analysis
Risk Factors of Age-Related Macular Degeneration in a Population-Based Study: Results from SHIP-TREND-1 (St...Med Sci Monit In Press; DOI: 10.12659/MSM.943140
12 Mar 2024 : Clinical Research
Preoperative Blood Transfusion Requirements for Hemorrhoidal Severe Anemia: A Retrospective Study of 128 Pa...Med Sci Monit In Press; DOI: 10.12659/MSM.943126
12 Mar 2024 : Clinical Research
Tissue Inhibitors of Metalloproteinase 1 (TIMP-1) and 3 (TIMP-3) as New Markers of Acute Kidney Injury Afte...Med Sci Monit In Press; DOI: 10.12659/MSM.943500
Most Viewed Current Articles
17 Jan 2024 : Review article
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
14 Dec 2022 : Clinical Research
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
16 May 2023 : Clinical Research
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
01 Jan 2022 : Editorial
Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...DOI :10.12659/MSM.935952
Med Sci Monit 2022; 28:e935952